 Human Progesterone(PROG) ELISA kit
Catalog No. CSB-E07283h
(96T)
This immunoassay kit allows for the in vitro quantitative determination of human PROG concentrations in serum, plasma and Cell Culture Supernates.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長期經(jīng)營ELISA試劑盒及抗體、細(xì)胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸/download(向客服人員索取原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an goat-anti-rabbit antibody. Standards or samples are then added to the appropriate microtiter plate wells with a HRP-conjugated PROG and antibody preparation specific for PROG and incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of PROG in the samples is then determined by comparing the
O.D. of the samples to the standard curve.
DETECTION RANGE
0.2 ng/ml-50 ng/ml. The standard curve concentrations used for the ELISA’s were 50 ng/ml, 15 ng/ml,2.5 ng/ml, 0.5 ng/ml, 0.2ng/ml.
SPECIFICITY
This assay recognizes human PROG. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human PROG is typically less than 0.2
ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.

MATERIALS PROVIDED
 
Reagent
Quantity
 
Assay plate
1
 
Standards (S1-S5)
5 x 0.5 ml
 
HRP-conjugate
1 x 6 ml
 
Antibody
1 x 6 ml
 
 
1 x 15 ml
 
Wash Buffer
 
 
 
(20×concentrate)
 
Substrate A
1 x 7 ml
 
Substrate B
1 x 7 ml
 
Stop Solution
1 x 7 ml
 

Standard
S 1
S 2
S 3
S 4
S 5
Concentration (ng/ml)
0.2
0.5
2.5
15
50

STORAGE
1          Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.
2          Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3          A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
TECHNICAL HINTS
1          Bring all reagents and plate to room temperature for at least 30 minutes before use. Unused wells need store at 2-8and avoid sunlight.
2          Wash Buffer If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
3          To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Sealers can not be reused.
6          Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1           Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2           Pipettes and pipette tips.
3           Deionized or distilled water.
4           Squirt bottle, manifold dispenser, or automated microplate washer.
 
SAMPLE COLLECTION AND STORAGE
1           Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediay or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cycles.
2           Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cycles.
3           Cell Culture Supernates Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.
1          Set a Blank well without any solution. Add 50μl of Standard or Sample per well. Standards need test in duplicate.
2          Add 50μl of HRP-conjugate to each well (not to Blank well), then add 50μl Antibody to each well. Mix well and then incubate for 1 hour at 37°C.
3          Fill each well with Wash Buffer (about 200μl), stay for 10 seconds and Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
4          Add 50μl of Substrate A and Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
5          Add 50μl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
6          Determine the optical density of each well within 10 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Average the duplicate readings for each standard, Blank, and sample and subtract the optical density of Blank. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the PROG concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1           The kit should not be used beyond the expiration date on the kit label.
2           Do not mix or substitute reagents with those from other lots or sources.
3           It is important that the Calibrator Diluent selected for the standard curve be consistent with the samples being assayed.
4           If samples generate values higher than the highest standard, dilute the samples with the appropriate Calibrator Diluent and repeat the assay.
5           Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
6           This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.

環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.1ianso.com,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會(huì)員登錄

×

請輸入賬號(hào)

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
97av在线视频| 偷国产乱人伦偷精品视频| 亚洲国产日产无码精品| 国产无人区码卡二卡三卡| 日韩激情无码免费毛片| 爆乳2把你榨干哦OVA在线观看| 大伊香蕉精品视频在线天堂| 福利资源在线| 国产网友自拍偷欧美激情| 国产精品毛片一区二区| 日韩一区二区在线视频| 亚洲最大激情中文字幕| 亚洲欧洲日产国无高清码图片| 亚洲欧美精品中文字幕在线| 2021理论片一级| 91精品久久| 亚洲AV综合色区无码一区爱AV| 精品一区二区三区免费毛片爱| 八戒八戒免费观看在线完整版| 国产精品福利在线播放| 24小时日本在线观看完整版| WWW.AV天堂.COM| 婷婷无套内射影院| 国产精品一卡二卡三卡| 国产精品伦一区二区三级视频| 中文在线а天堂中文在线新版| 中文字幕5566看片资源| 少妇白洁小说在线阅读| 欧美色欧美亚洲日韩在线播放| 久久热这里只有精品18| 男人趴在美女身上亲胸| 精品无码三级在线观看视频| 午夜男女爽爽影院免费视频| 玩弄放荡人妻少妇系列视频| 日本精品久久久久护士| 欧美日韩国产高清视频| 看AV免费毛片手机播放| 亚洲欧美在线视频观看免费| 午夜精品久久久久久久久久| 100至499| 久久久久久亚洲av午夜|